PACCAR PX-6 CM2150 (2007-09) Fault Code: 111 PID: SID 254 SPN: 629 FMI: 12 Electronic Control Module Critical Internal Failure - Bad Intelligent Device or Component.

PACCAR PX-6 CM2150 (2007-09) Fault Code: 111 PID: SID 254 SPN: 629 FMI: 12 Electronic Control Module Critical Internal Failure - Bad Intelligent Device or Component. Error internal to the electronic control module (ECM) related to memory hardware failures or internal ECM voltage supply circuits.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

This fault code can only be caused by an internal ECM problem. Repairs are not possible for the ECM.

Possible repairs:

1)Replace the ECM.